Quick-Action Precise Thermometer Lovibond ® CHECKIT ® micro WP Temperature.

Description of the unit:
The Lovibond ® CHECKIT ® micro WP temperature precise thermometer is ideal
for quick, uncomplicated core temperature checks in all industries i.e.
swimming pool, caterers, hotels, canteens, supermarkets etc.
The compact, practical thermometer is handy, fits inside a pocket and has a thin,
robust measuring tip for improved response.

Advantages:
- Quick check using a thin, robust measuring tip;
- Monitors limit values;
- Wide range with high measuring accuracy
Scope of delivery
Included: TopSafe, robust, waterproof, hygienic and dishwasher-safe protection
case (IP 67) and wall/belt holder Lovibond ® CHECKIT ® micro WP Temperature,
precise thermometer with probe protection cap and battery.

Technical data:
Range: -50...+230°C/-58...+446°F;
Operating Temperature: +20...+50°C/-4...+122°F;
Storage Temperature: -40...+70°C/-40...+158°F;
Battery type: Lithium battery (2032);
Material/Housing: ABS;
Display: LCD 1-line;
Battery life: 250h.

Special offer:
List price: 89,50 EUR
Special price: 44,75 EUR*
* Minimum order quantity, 3 pieces
Order code: 19 47 20

29.04.03

Tintometer at the ACHEMA from May 19 to 24, 2003!

The 27th ACHEMA fair will be taking place at the trade fair centre in Frankfurt/Main from May 19 to 24, 2003. The ACHEMA is the world’s leading forum for chemical technology, environmental protection and biotechnology and provides all exhibitors with an ideal platform for the presentation of their product innovations.
Tintometer will of course be presenting its products and services to the trade public at its own booth, where we will be showing the latest generation of Lovibond® meters and reagents, such as:
- PC MultiDirect photometer;
- OxiDirect ® BOD meter;
- Handheld meter range:
•SensoDirect 200,
•SensoDirect 100,
•CHECKIT ® micro WP;
- Vario Powder Pack programme, suitable also for use with Hach-Photo-meterSystems.
Whether you are a first time visitor or a new or regular customer, our trade fair team looks forward to meeting you and getting to know you better.
We hope to see you there! Hall 6.1, Booth F29-G30

30.04.03

Lovibond ® General Catalogue 2003 in English.

The English-language version of our general catalogue is now available.
Following the excellent response to the German-language catalogue, we have revised and optimised the English version and made it even more reader-friendly. The new catalogue features an index to help you find the products you are interested in easily and quickly.
The introductory section contains an overview of our products and production operations. This overview briefly outlines the production of tablet reagents, vial tests, Vario Powder Packs and liquid reagents.
The catalogue is available through our sales department (sales@tintometer.de) free of charge as a print version or CD-ROM;
it can also be downloaded at www.tintometer.de.
We look forward to hearing your comments and suggestions!
Lovibond ® General Catalogue 2003 in English

30.04.03

CLAISSE is the world leader in sample preparation by fusion for XRF analysis. We will attend Achema 2003 and be at the stand Hall 5.1 - F29-F30.

13.05.03

- Our brand new Biohazardous Disposal Pouches and Rubber Pipet Fillers are now in stock and available for shipment.
- HS23042P 100 Pouches to a Pack-Special Dealer Cost is $19.95 for orders placed before May 31, 2003.
- HS20632A Black Pipet Filler-Special Dealer Cost is $1.85 for orders placed before May 31, 2003.
- HS20632B Red Pipet Filler- Special Dealer Cost is $1.85 for orders placed before May 31, 2003.
- HS20632C Blue Pipet Filler- Special Dealer Cost is $1.85 for orders placed before May 31, 2003.

14.05.03

Heathrow Scientific is going to once again exhibit at the upcoming Achema Show held in Frankfurt Germany. The trade show begins on Monday, May 19th. Our stand will be located in Hall 5.1, B32.

If you are going to be at the show please stop by to meet with us. Liz Boberg from Product Development, Sean McGhee from our Sales Department and Jim Dahl will be on hand.

We will have some good German beer on hand, so do stop by!

15.05.03

Energy Dispersive micro X-ray fluorescence spectrometer

The new Shimadzu series of Micro EDX instruments combine the resolution and flexibility of energy dispersive instruments with the speed and convenience of non dispersive instruments.
Microanalysis of electronic components, circuit boards, and foreign matter in foods was difficult with conventional fluorescence X-Ray spectrometers due to poor sensitivity at a small illuminated size and insufficient resolution even at full X-Ray intensity. However, the new Shimadzu series of Micro EDX spectrometers achieves high sensitivity and high resolution analysis of such samples down to a minimum measured diameter of 50 microns.
Key micro EDX features
• Polycapillary X-Ray Lens High Sensitivity Micro Analysis (50ґm)
•Analyze Light to Heavy Elements in Air
•Dual CCD Camera (High & Low Magnification) Simple positioning of the Sample
•Element Mapping Maps Multiple Elements Simultaneously
•5 Primary Filters Provided as Standard Automatically Eliminates Undesirable X-Rays from the Tube & Improves Signal to Noise Ratio
•Transmission Imaging Unit (Optional) Simultaneous Measurement of Transmission X-Ray Images
•Accommodates Samples up to 200(W) x 300(D) x 40(H)mm
•Real Time Scaling Stage Viewer Function Displays Entire Stage Simple mouse click on analysis position moves the stage to target

15.05.03

Net sales for the three months ended March 31, 2003 increased 22% to $29.0 million, compared to $23.8 million for the three months ended March 31, 2002. After elimination of favourable currency effects, revenue growth was 6%. Gross margins for the quarter continued to improve, increasing to 40.3%, compared to 38.3% for the first quarter of 2002.
Cash and cash equivalents totaled $48.6 million as of March 31, 2003. During the first quarter 2003, the Company paid off total debt of approximately $1.7 million.
Strong sales of X-ray fluorescence systems, including the S4 Pioneer, and improved after-market sales were the drivers of growth, although $3.6 million of positive currency affects and $1.6 million of revenues from last year’s acquisition of MAC Science Ltd aqlso played a significant role.

<<<
<<
<
11 12 13 14 15 16 17 18 19 20
>
>>
>>>

 
Russian
Registration
Login
Forgot your password?
FAQ
 
Subscription for news

Unsubscribe
 
Link to Lab.ru
Lab equipment in the focus of view
 
003973 Powered by DSGroup | version 2.0 | © neoLab.ru 1998-2024 Russian English
 
Rambler's Top100      Яндекс цитирования  Valid HTML 4.01!  Ссылки