27.01.03 New development: Tamson circulation cooler model "TLC30-5" which has a temperature range of - 30 up to + 60°C with an accuracy better than ± 0.05 K.

This circulation cooler can be used for several purposes e.g. cooling ASTM testing instruments, general cooling etc.

The circulation cooler is very compact and the sizes are 420x265x565mm (L x W x H).
01.09.02 Reference oils: Standards for viscosity measurrements.

Primary standard
Conforms to ASTM D2162
Values certified 20, 25 40, 50 and 100°C
2 years shelf life
Contents 500ml per bottle
01.08.02 New development: bath/circulator "TC6". Thermostatic bath and circulator 6ltrs bath.

The TC6 can both be used as circulator or bath. The bathfluid is heated via a microprocessor controlled heating element. When working below ambient temperature cooling fluid can be circulated through the cooling coil to lower the bath temperature. The bath is equipped with fluid level detection and drain located at the backside of the apparatus. The microprocessor controlled heating with autotune function guarantees precise temperature controll. The top unit can easily be detached from the bath when unscrewing two small handweels located at the back. This enables full and easy acces to the bath compartment for cleaning.

The bath temperature can be set to a maximum of 250°C(482°F) in steps of 0,1degree. The overall system accuracy is ±0,05°K

A pressure pump provides circulation in the bath or via an external circuit. The pressure of the pump is 300 mBar at 7 ltrs per minute.

The bath conforms to CE regulation. It further is equiped with multiple safety features in order to guarantee safe around the clock operation. A mechanical safety thermostat protects the bath against high temperatures and will automatically reset itself after switching the bath off and on again.The safety thermostat can be set between ambient and +300°C. In case of overtemperature powerelectronics and motor are fully switched off. The pump motor is protected against mechanical overload via a resettable fuse.

Standard available in °C, on request in °F.

Accessories - Leveling platform.
01.07.02 New development: cooling bath/circulator "TLC40". Low temperature 10L bath/circulator.

This type of cooling circulator is mostly used for replacing tapwater used for cooling purposes in laboratory equipment or processes. The bath contence is 11 litres. The drain located at the back provides easy removal of the bath fluid. Low fluid level is detected electronically.

The used cooling system is ozone friendly, so it doesn't contain any CFK/HCFK gas.
With the compressor running continuously, the fluid temperature is regulated through an electronic controlled heater.

The TLC40 offers following working range:
-45 to +20°C / -49 .. 68°F
The setpoint can be set in steps of 0,1°. The overall system accuracy is better than ±0,1°K. Standard available in °C, on request in °F.

A pressure pump provides circulation in the bath or via an external circuit. The pressure of the pump is 300 mBar at 7,5 ltrs per minute.

The bath conforms CE regulation. It is further equiped with a mechanical adjustable and resettable safety thermostat.
01.06.02 New development: cooling bath/circulator "TLC80". Low temperature 11L bath/circulator .

The TLC80-11 is a low temperature circulator with a bath contents of 11 litres. The minimum temperature which can be reached is minus 80°C. At this low temperature the heat removal capacity lies around 50 watts. The drain located at the back provides easy removal of the bath fluid. Low fluid level is detected electronically.

The used cooling system is ozone friendly, so it doesn't contain any CFK/HCFK gas.

With the compressor continuously running, the fluid temperature is regulated via an electronic controlled heater.

The working temperature range is : -80 to ambient (-112°F .. ambient)

The setpoint is adjustable in steps of 0,1°C. The overall system stability is better than ±0,05°K as can bee seen in the graph.

Standard available in °C, on request in °F.

A pressure pump provides circulation in the bath or via an external circuit. The pressure of the pump is 300 mBar at 7 ltrs per minute.

The bath conforms CE regulation. It is further equiped with a mechanical adjustable and resettable safety thermostat.

Available in 230 or 115Volt
01.07.00 New developed cooling bath/circulator "TLC2". Low temperature 5.5L bath/circulator.

The TLC2 is recently developed especially to be used with a TV2000 or TV4000 viscometer baths. This combination enables extremely stable "TV" -bath temperatures down to 10°C. Instead of using the TLC2 as a cooling circulator (and i.e. replacing tapwater) it can of course also be used as a low temperature thermostatic bath. The bath itself is 15 mm deep, contains 5.5 litres of fluid and the bath opening is 100*150mm and provided with a lid. Due to its special design the system is extremely quit and compact, saving costly laboratory space.

The cooling system inside the TLC 2 is ozone friendly and doesn't contain any CFK/HCFK gas.

The TLC 2 combines a wide temperature range and a maintenance free -long life- cooling system. Accurate temperature regulation is provided by a microprocessor controlled PID system also enabling an "Autotune" function for optimum setting of the temperature regulation. The cooling system provides rapid cooling down of the 5.5 ltrs bath contence.

The working temperature range is : -10 to +100°C / 14..212°F
The setpoint can be set in steps of 0,1°K. The overall system accuracy is ±0,1°K. Temperature readout in 0,1°K
Standard available in °C, on request in °F.

A pressure pump provides circulation in the bath or via an external circuit. The pressure of the pump is 300 mBar at 7,5 ltrs per minute.

The bath conforms CE regulation. It is further equiped with a mechanical adjustable and resettable safety thermostat.
01.04.00 FREE communication software between a Windows computer and TAMSON bath at www.tamson.com.
01.03.00 New "PDF" with Product Matrix revised with new products at www.tamson.com.
01.02.00 New "PDF" manuals for TV- and TxxxxE series at www.tamson.com.
15.01.00 Need a special or adapted product?

Contact us now!

Do not look any further. We can adapt, or completetely build a single machine for you. Please contact us via e-mail or by fax with a detailed description of what you're looking for. We will contact you free of charge and without any obligation.
     